KINGSPAN TF70 PDF

Kingspan Therma TF70 Floorboard; high performance insulation for floors with a continuous thermal performance, lasting a constructions life cycle. Kingspan TF70, TW55 and TP10 are readily available in the following product thicknesses 20mm, 25mm, 30mm, 40mm, 50mm, 60mm, 70mm, 75mm, 80mm. Thermafloor TF70 is a high performance, fibre free, rigid thermoset insulation core faced on both sides with a low emissivity composite foil facing which is used .

Author: Akir Akitaur
Country: Egypt
Language: English (Spanish)
Genre: Career
Published (Last): 9 February 2008
Pages: 141
PDF File Size: 14.89 Mb
ePub File Size: 18.30 Mb
ISBN: 702-4-57262-122-3
Downloads: 55550
Price: Free* [*Free Regsitration Required]
Uploader: Doll

To find out more about the cookies we use, or to change your cookie preferences i. Manufactured to order are the following thicknesses 45mm, 55mm, 65mm, 85mm, mm, mm, mm, mm and mm. The Model School Inchicore is a conservation of and addition to a historic Irish primary school in order to adapt the school to kongspan day requirements. A thin sand blinding may be used to achieve a continuous level surface free from projections over rolled hardcore. Kingspan TF70 30mm, 10 x 1. The surface of the slab should be smooth, flat and free from projections.

Measure the distance between the joists prior to cutting the boards as spacings can vary.

Click to download in a separate browser window. Concrete slabs should be allowed to dry out fully prior to the installation of Kingspan Thermafloor TF70 average 1 day per mm of slab thickness. Modified to include board facings, the boards achieve a resistance far greater than MN.

Rough cast slabs should be levelled using a thin sand blinding to ensure boards are continuously supported. Ensure that safe methods of cleaning are used, as recommended mingspan the suppliers kingxpan the spilt liquid. Kingspan TF70 kingspa, 8 x 1. Construction work started immediately and was completed in with the official opening taking place on May 2nd A range of premium and high performance products has been installed on a stunning new beachfront home on the Isle of Wight, featured on Grand Designs.

The insulation core is resistant to short—term contact with petrol and with most dilute acids, alkalis and mineral oils. High performance floor insulation Kingspan Thermafloor TF70 is a high performance insulation with a fibre-free rigid thermoset polyisocyanurate PIR core.

  KKS TAGING PROCEDURE PDF

High performance rigid thermoset insulation — thermal conductivity 0. If correctly applied, the TF70 Board has an indefinite life.

Kingspan TF70 25mm, 12 x 1. Concrete slabs should be allowed to dry out fully prior to the installation of the insulation boards average 1 day per mm of slab thickness. The top of the strip of insulation board should kihgspan level with the top of the floor screed and the bottom should be level with the bottom of the horizontal floor insulation, and closely butted up to it.

Products from our Kooltherm and Therma ranges have helped to transform a derelict water tower in North Yorkshire into a striking family home. Where there are long over 5 tf0uninterrupted lengths of timber floor boards, proprietary intermediate expansion joints should be installed on the basis of a 2 mm gap per metre run. Select products below to see pricing structure Use product tick-boxes to select required products Add to Basket Kingspan TF70 20mm, 15 x 1.

If two layers of insulation are required, they should be horizontally offset relative to each other so that, as far as possible, the board joints in the two adjacent layers do not coincide with each other.

Floor insulation | Thermafloor TF70 | Kingspan | Great Britain

Specifications Thermal conductivity 0. Subject to product availability locally, and vehicle delivery slots. Product brochure Useful links Case studies. TF70 is faced on both sides with a low emissivity composite foil facing lingspan is highly resistant to the transmission of water vapour.

Any narrow gaps between battens and perimeter wall should be insulated by specially cut pieces of board.

50mm Kingspan Thermafloor TF70 PIR Insulation Board | Floor Insulation

Ensure battens are of the appropriate thickness, so that the insulation boards finish flush with their top surface unless an underfloor heating system is to be used. Common applications for this product include Test – BS —3: Kingspan TF70 20mm, 15 x 1. The most popular board sizes may be available from stock.

Architects Consarc Conservation in Belfast worked closely with the main contractor Woodvale Construction Company to bring life back to this wonderful building which has been vacant tt70 Beam and block floors should be level and grouted. Gaps less than 25 mm wide should be filled with expanding urethane sealant. Order before 10am for next working day delivery. Adhesives containing such solvents should not be used in association with this product.

  3.5 LIBRA MORTIS PDF

These boards are faced on both sides with a low emissivity composite foil facing that is highly resistant to the transmission of water vapour. The insulation core is not resistant to some solvent—based adhesives systems, particularly those containing methyl ethyl ketone.

We use cookies on our website www. The size of the battens selected should ensure that, when installed, the top surface of the insulation boards are flush with the top of the battens.

Kingspan Insulation Ltd For queries relating to insulation boards, cavity closers or membranes. Kingspan TF70, TW55 and TP10 are readily available in the following product thicknesses 20mm, 25mm, 30mm, 40mm, 50mm, 60mm, 70mm, 75mm, 80mm, 90mm, mm, mm, mm and mm. To tr70 out more about the cookies we use, or to change your cookie preferences i.

Kingspan TF70 Thermawall Rigid PIR Insulation Boards

Fairways A range of premium and high performance products has been installed on a stunning new beachfront home on the Isle of Wight, featured on Grand Designs. We kngspan endeavour to source the required stock, however, we may need to mix and match equivalent products from multiple manufactures, suppliers and depots.

The insulation boards should be cut to fit snugly between the floor joists.

Installation Between Battens under a Timber Floor Concrete slabs should be allowed to dry out fully prior to the installation of the insulation boards average 1 day per mm of slab thickness.

Kingspan Thermafloor TF70 is not suitable for installation directly over timber joists.

Pannal Water Tower Products from our Kooltherm and Therma ranges have helped to transform a derelict water tower in North Yorkshire into a striking family home.