ALLEN BRADLEY 1305 VFD MANUAL PDF

However, using an Allen-Bradley motor with your drive removes the . Н Installation guidelines called out in Appendix D of the User’s Manual. Installation Instructions IN. May, Allen-Bradley. Dynamic Brake. Cat. No. KAA KBA03, KBA06, KBA Table of Contents. Find great deals for Allen Bradley Adjustable Frequency AC Drive User Manual. Shop with confidence on eBay!.

Author: Dagar Zulkisida
Country: Poland
Language: English (Spanish)
Genre: Spiritual
Published (Last): 3 January 2004
Pages: 245
PDF File Size: 7.38 Mb
ePub File Size: 3.90 Mb
ISBN: 692-7-45827-195-1
Downloads: 73273
Price: Free* [*Free Regsitration Required]
Uploader: Saran

Replace the Communication cable. Check the motor for grounded phase. DC Braking cannot be used with a synchronous motor. Reset your drive to the factory default settings. Connect proper adapter or change active frequency source. brasley

Allen Bradley Adjustable Frequency AC Drive User Manual | eBay

Open Pot Al,en – F9 An external pot is connected and the ground lead of the pot is disconnected, creating a potential drive overspeed hazard. Overload Fault – F7 Internal electronic overload trip. Inspect for short at the drive output or excessive load conditions on the motor, especially cable capacitance to ground.

Inspect for blocked or contaminated heat sink fins.

Unplug the HIM from the cable or drive and reconnect it. Overspeed Fault – F25 Internal error.

  CRANE 410M PDF

Overtemperature Fault – F8 Temperature sensor detects excessive heat. Inspect fault buffer for fault code requiring reset. A longer acceleration tiime or a lighter load may be required. Correct the cause of the fault and manually clear by cycling the stop command or cycling power. Check for excess load, improper DC boost setting, DC brake volts set too high or other causes of excess current.

1305 AC Drives

Check the external potentiometer circuit at TB2, terminals 1, 2, and 3 for a disconnected alleh. D Micro Programmable Logic Controllers. Error 5 – Drive is running while attempting download. Error 5 – Drive is running while attempting download Repeat operation.

Verify that all parameters have been programmed. Verify that the parameter has been programmed correctly. Check programming of [Curr Lim Trip En] parameter. Serial Fault – F10 An active local bus adapter is disconnected while it possesses control of a local bus function. Drive Reset Fault – F22 May occur on power-up. The Adjustable Frequency AC drive is available with ratings 0.

Capabilities of drive are different than the master drive. Hz Sel Fault – F30 An unconnected adapter has been selected as manuzl active frequency source. DC Bus voltage fell below the minimum value. The last parameter programmed will be displayed on the top line.

  ASPHYXIANT CULTURE PDF

Allen Bradley Adjustable Frequency AC Drive AB

The Adjustable Frequency AC Drive is a variable speed drive designed to control the speed of three-phase AC induction motors in a variety of demanding applications where flexibility, performance and ease of use are essential. Inspect to ensure that the ambient temperature limit has not been exceeded. Bus overvoltage can also 3105 caused by motor reeneration. Check cable connection from main control board to power board. Error 2 – The number of parameters in saved profile does not equal master number.

Stop drive, then re-run download. If the motor is drawing excessive current, the motor load is excessive and will not allow the bradleey to accelerate to set speed.

Reprogram Fault – F48 May occur when drive parametersare reset to default settings. Press Enter to continue download. Unplug the HIM from the cable or drive, then reconnect it. Inspect for breaks in communications line. Hz Err Fault – F29 No valid operating frequency.